Skip to content
Conceptual project

Business hotel, 88 rooms

Central room management, an arrival scene triggered on first badge, addressable fire detection and energy supervision by zone.

Building type
Hotels
Floor area
6 100 m²
Context
A site that never closes
Brief
88 rooms and public areas
Business hotel, 88 rooms — 88 rooms and public areas

The brief

What the building demands

  1. 01A building that never closes: no intervention may interrupt operation
  2. 02Ending the habit of cooling 88 rooms when half are empty
  3. 03Fire safety beyond reproach, since it is the condition of operating at all
  4. 04Front desk staff able to act without an engineering background

The architecture

The response, layer by layer

The same order of dependency as on every project we run: energy first, supervision last. Each layer links to the discipline that handles it.

  1. 01
    ENERGYEnergy

    Metering by zone and by use, with photovoltaic generation covering the daytime base load of the public areas. Discipline

  2. 02
    ELECTRICALElectrical

    Redundancy on vital circuits — lifts, security, IT — with changeover the guest never notices. Discipline

  3. 03
    NETWORKNetworks

    Guest and operations networks strictly separated, with coverage validated room by room by measurement. Discipline

  4. 04
    SECURITYSecurity

    Video protection of circulation and entrances, retention calibrated on the legal period and no longer. Discipline

  5. 05
    ACCESSAccess control

    Online locks, rights expiring at checkout, staff access traced by service zone. Discipline

  6. 06
    FIREFire

    Addressable detection to EN 54 and ISO 7240, compartmentation interlocks, reporting to reception and to security. Discipline

  7. 07
    AUTOMATIONAutomation

    Arrival scene on first badge, energy isolation when the guest leaves, setpoints bounded by the operator. Discipline

  8. 08
    MONITORINGSupervision

    Energy supervision by zone, drift alerts and monthly operating reports.

Technologies

What we bring to bear

  • KNX
  • DALI-2
  • EN 54
  • ISO 7240
  • IEEE 802.11ax
  • Modbus TCP

Open, documented standards rather than closed systems: an installation must remain serviceable and extendable by another integrator.

In use

What this architecture produces

  • An empty room stops consuming: energy follows real occupancy.
  • The guest walks into a room already at temperature and already lit.
  • Reception can see the building's technical status without calling maintenance.

This record describes a reference architecture. Measured performance figures are published only for completed sites, with the client's agreement.

Tell us about your project

Describe the building. We will describe the infrastructure.

A study, a detailed cost breakdown discipline by discipline, and one point of contact from the first survey through to maintenance. We reply within two working days.

Message us on WhatsApp