Skip to content
Conceptual project

Coworking floor, 300 desks

Wi-Fi engineered for 300 simultaneous desks, room booking tied to access control, and lighting that follows a circadian rhythm.

Building type
Offices
Floor area
1 700 m²
Context
Shared workspace
Brief
Open floor and meeting rooms
Coworking floor, 300 desks — Open floor and meeting rooms

The brief

What the building demands

  1. 01Three hundred people on video calls at once, without saturation
  2. 02Members coming and going: access rights change every day
  3. 03Visual comfort that holds over a full working day
  4. 04Operation by a front-desk team, not by an IT department

The architecture

The response, layer by layer

The same order of dependency as on every project we run: energy first, supervision last. Each layer links to the discipline that handles it.

  1. 01
    ENERGYEnergy

    Metering by zone, with scheduled shutdown of unoccupied desk areas outside opening hours. Discipline

  2. 02
    ELECTRICALElectrical

    Socket density calculated on real use, with floor boxes that can be moved as the layout changes. Discipline

  3. 03
    NETWORKNetworks

    Wi-Fi 6E access points positioned by radio survey, isolated guest network, quality of service prioritising video calls. Discipline

  4. 04
    SECURITYSecurity

    Video protection of entrances and high-value areas, never of the desks themselves. Discipline

  5. 05
    ACCESSAccess control

    Mobile credentials tied to the membership, with a room opening only for whoever booked it. Discipline

  6. 06
    FIREFire

    Detection covering both open floor and enclosed rooms, with evacuation messaging intelligible over the ambient noise. Discipline

  7. 07
    AUTOMATIONAutomation

    Circadian lighting: cooler colour temperature in the morning, warmer late in the day, dimmed on daylight. Discipline

  8. 08
    MONITORINGSupervision

    Occupancy by zone and by room — a factual basis for adjusting the commercial offer.

Technologies

What we bring to bear

  • IEEE 802.11ax
  • ISO/IEC 11801
  • DALI-2 Tunable White
  • OSDP
  • EN 54

Open, documented standards rather than closed systems: an installation must remain serviceable and extendable by another integrator.

In use

What this architecture produces

  • Video calls hold at full load, at peak hours.
  • A suspended membership closes the corresponding doors immediately.
  • Occupancy data shows which rooms deserve to be enlarged.

This record describes a reference architecture. Measured performance figures are published only for completed sites, with the client's agreement.

Tell us about your project

Describe the building. We will describe the infrastructure.

A study, a detailed cost breakdown discipline by discipline, and one point of contact from the first survey through to maintenance. We reply within two working days.

Message us on WhatsApp